Menu
Tolerance On Flatness
The unflatness across the strip (also called cross camber and cross bow) is expressed as a percentage of the strip width. The unflatness along the strip, sometimes called coil-set, is also expressed as a percentage. Unless otherwise agreed upon the measuring length = the strip width for flatness measurements along and across the strip. Influence of possible residual stresses from slitting shall be excluded.
| Tolerance | Maximum permitted deviation class(% of nominal strip width) |
|---|---|
| P0 | – |
| P1 | 0.4 |
| P2 | 0.3 |
| P3 | 0.2 |
| P4 | 0.1 |
| P5 | As per customer`s special requirement |
| Tolerance class | Strip Width | |||||||
|---|---|---|---|---|---|---|---|---|
| 8 – (20) mm | 20 – (50) mm | 50 – (125) mm | 125mm~ | |||||
| Measuring length | ||||||||
| 1m | 3m | 1m | 3m | 1m | 3m | 1m | 3m | |
| Maximum allowed straightness deviation (mm) | ||||||||
| R1 | 5 | 45 | 3.5 | 31.5 | 2.5 | 22.5 | 2 | 18 |
| R2 | 2 | 18 | 1.5 | 13.5 | 1.25 | 11.3 | 1 | 9 |
| R3 | 1.5 | 13.5 | 1 | 9 | 0.8 | 7.2 | 0.5 | 4.5 |
| R4 | 1 | 9 | 0.7 | 6.3 | 0.5 | 4.5 | 0.3 | 2.7 |
| R5 | As per customer`s special requirement | |||||||